Hunter

klammer links
HUNTER
klammer rechts
Brochure

HUNTER

On the hunt for leaks

  • Optimized for just one application – Systematic gas pipeline network monitoring
  • Rapid reaction time to avoid „over runs“ in the leaking area
  • Carpet Probe TS14 with a newly developed material, which combines the highest possible abrasion resistance with flexibility and suitability for use in a wide range of temperatures
  • HUNTER can be supplied with an optional Bluetooth module
  • Memory with a capacity of over 250 operating hours with data storage every second
  • With a weight of just 1.1 kg and the recommended lap belt as a carrier system, the gas detector can work with the device in complete comfort for more than eight hours

A faster reaction time not only ensures that an alarm is triggered sooner. The alarm threshold may otherwise not be reached at all for small concentrations of gas and minor leaks. A „over run“ in the leaking area can therefore not be ruled out.
In addition to the gas leak detector, the probes also play a key role. The construction of the probes contributes significantly to the quality of the samples taken. In this area too, Esders is once again entering entirely new territory. The carpet mat is made from a newly developed material, which combines the highest possible abrasion resistance with flexibility and suitability for use in a wide range of temperatures. This has enabled us to more than double the service life of the carpet mat.

Technical data
Display LCD graphic display 128 x 64 pixels, illuminable
Display of measured value, maximum value and bar graph
Power supply NiMH battery pack, 4,8 Volt, 3,8 Ah
Operating temperature -15°C to +50°C
Operating time (without backlight) > 10 hours incl. Bluetooth- transmission
> 11 hours without Bluetooth- transmissions
Charging Charging cradle supplied by 12 Volt or 230 Volt,
charging time approx. 5 hours
Data Store Flash memory 4 Mbyte for more than 1 Mio. measurement values,
Documentation of the sensitivity tests
Protection category IP 54
Dimensions 168 x 90 x 80 mm without couplings
Weight approx. 1.100 g, incl. battery pack
Measurement principle Semiconductor sensor
Measurement range 0 to 1.000 ppm CH4, Resolution: 1 ppm, 5 ppm
0,1 to 2,2 Vol.% CH4, Resolution: 0,1 Vol.%
Response time T90 ≤ 4 seconds for CH4 (Methane)
Pumping capacity > 40 l/h, > 300 mbar