GOLIATH-W
Work place monitoring and bar hole testing
- Very quick initial break-in phase and extremely short reaction time when measuring CH4 and CO2
- Oxygen sensor and up to three toxic gas sensors are available as an option
- Optional pressure measuring up to 2.000 hPa
- Data readout to PC directly via charging tray
Work place monitoring and air control in confined spaces are permanent part of work processes in the fields of gas and water supply and waste water treatment. GOLIATH-W is ready for operation within a short break-in phase and ensures clear and rapid results. The robust and shockproof device is easy to handle. All measuring data are indicated on the clear and illuminable display.
Technical data | |
---|---|
Display | LCD graphic display 128 x 64 pixels, illuminable |
Power supply | NiMH rechargeable battery pack |
Operating temperature | -10°C to +40°C |
Operating time (without backlight) | > 9 hours |
Charging | Charging cradle supplied by 12 V or 230 V, Charging time approx. 5 hours USB connection (for 500 mA), charging time approx. 8 hours |
Data Store | Flash memory 4 Mbyte for more than 1 Mio. measurement values |
Protection category | IP 54 |
Dimensions | 200 x 100 x 87 mm without couplings |
Weight | approx. 1,200 g |
Explosion protection ATEX | BVS 09 ATEX E 079 X – Ex II 2G ib d IIB T3/T4 Gb |